問題 #43
Which of the following is most appropriate to coordinate ceiling-mounted HVAC diffusers?
答案:D
解題說明:
Reflected ceiling plans (RCPs) show locations of diffusers, lighting, ceiling grids, etc. Critical for coordinating mechanical with electrical and architectural elements. Related to Objective 3.1: Coordination of disciplines.
問題 #44
A family-owned apple farm in the Upper Midwest is taking advantage of a change in the local zoning code that added a new Agri-Tourism class in the existing farm zone. This allows the Owner to build a new facility on their existing site. The building will be open to the public and include a brewery, distillery, tap room, and market. The architect is ready to submit the drawings to the Owner for the 50% construction documents review.
To accommodate a compressed construction schedule, the Owner will be utilizing a design-build process. The Contractor has submitted the Pre-Engineered Metal Building (PEMB) shop drawings to the Architect for review, due to the lead time on this critical path item. Once construction begins, farming operations must be able to continue uninterrupted.
Key project information includes:
* Brewing and distilling will operate year-round.
* Brewery will initially include four fermenting tanks. Owner has requested space for at least two additional tanks. Potential expansion will be based on future sales.
* Distillery will produce 16% alcohol, which is classified as a flammable liquid. Fire separations are required.
* Tap Room is designed with seating for 300 people, not including exterior patio seating. It will have views to the working orchards and the historic buildings on site.
* Tap Room is scheduled to be open from August through November. Owner would like options to extend operating dates based on popularity.
* The Market area will feature local farm products and is not conditioned.
* Entire building will be fully sprinklered.
* Selected building materials are low-maintenance, as requested by the Owner, for durability and to reflect the nature of a working farm.
* Mechanical and electrical systems will be hung from the building structure. These loads are included in PEMB shop drawings.
* Public water and sewer is not available at the Project Site.
* Occupancy sensors are included to reduce utility costs and achieve energy conservation requirements.
The following resources are available for your reference:
* Architectural Drawings, including plans, elevations, sections, and schedules
* Consultant Drawings, including structural, HVAC, power distribution, and plumbing
* PEMB Shop Drawings
* Design and Construction Schedule
* Specification Excerpts, showing relevant spec sections
* IBC and ADA Excerpts, showing relevant code and accessibility sections
* After reviewing the documents, the architect discovers a coordination issue in the corridor.
The owner is concerned about elevated noise levels in the Tap Room when fully occupied. The current design utilizes a 2 x 2 acoustic ceiling tile system installed above the fans. An acoustical engineer recommends noise mitigation through limiting reverberation time (RT) to 2.0 seconds or less in the space. This can be achieved by the provided ceiling material options and their corresponding area.
What should the architect recommend that will minimize additional project costs while providing the recommended acoustical solution?
答案:A
解題說明:
1. Problem Summary
* Goal: Reduce reverberation time (RT) in the Tap Room to 2.0 seconds or less.
* Current design: 2' x 2' acoustic ceiling tile system (RT = 2.0 seconds) installed above fans.
* Constraint: Minimize additional project cost.
* Recommendation from acoustical engineer: Use materials to achieve target RT without redesigning the space.
2. Review of Table Data
Material
RT
SF
SF Cost
Cementitious Wood Fiber Panels (1")
2.0
448
$12.64
Cementitious Wood Fiber Panels (2")
1.8
384
$18.95
2x2 Acoustical Ceiling Tile (15/16")
2.0
900
$8.81
Acoustical Sound Board (1")
1.6
256
$18.23
3. Interpretation of RT Values
* Current 2x2 Acoustic Ceiling Tile: RT = 2.0 seconds # meets the target exactly.
* However, fans may reduce the acoustic performance by reflecting or scattering sound, so supplemental absorption may be needed.
* Adding Acoustical Sound Board (RT = 1.6) above the existing tile system will improve absorption and lower RT below 2.0 seconds.
4. Cost & Constructability
* Retaining the current ceiling layout and simply adding a layer above is:
* Least disruptive to current design.
* Avoids redesign of the ceiling cloud layout.
* Minimizes schedule impact (critical for design-build with compressed schedule).
* Replacing with wood fiber panels (1" or 2") would require removal of existing tile, redesign of suspension, and higher cost/SF.
5. Why Other Options Are Incorrect
* A. Remove fans: This addresses air movement, not RT. Removing them does not guarantee RT improvement and conflicts with HVAC design intent.
* B. One cloud + 1" wood fiber panels: Reduces coverage area and may not meet RT goal; also costly and disruptive.
* C. One cloud + 2" wood fiber panels: Even more costly, same redesign problem as B.
* D. Retain tiles and add sound board above: Achieves RT < 2.0, minimal disruption, cost-effective vs.
full replacement # best option.
6. NCARB ARE 5.0 PDD Study Guide References
* Content Area: Building Systems Integration - Acoustics
* Reference Sources:
* Architectural Graphic Standards - Acoustic material properties
* Mechanical and Electrical Equipment for Buildings (MEEB) - Room acoustics and reverberation control
* ASTM C423 - Sound Absorption and Sound Absorption Coefficients by the Reverberation Room Method
問題 #45
In winter conditions, when the outdoor air is below freezing and the indoor humidity is maintained at 40 percent relative humidity for 24 hours a day, ice forms on the exterior surface of the stone facing.
Which of the following elements is missing from the building wall section?
答案:D
解題說明:
With outdoor below freezing and indoor RH ~40% continuously, interior vapor will migrate outward. If a proper interior-side vapor barrier/retarder is missing, moisture moves through the wall and can condense and freeze at the cold exterior stone, forming visible ice. Insulation, air spaces, or rain screens help heat/moisture management, but the symptom (ice due to vapor diffusion) points specifically to the lack of an interior vapor barrier in a cold-climate assembly.
PDD references: Moisture control & vapor retarder strategy in cold climates; condensation diagnostics (ASHRAE Fundamentals; ARE 5.0 PDD-Envelope moisture control).
問題 #46 
Refer to the exhibit.
What is the horizontal member indicated by the arrow in the wall-floor assembly?
答案:B
解題說明:
The arrow in the wall-floor assembly indicates a horizontal structural member attached to a wall, used to support the end of a floor joist. This is called a ledger.
Ledger: Typically a dimensional lumber or engineered wood member fastened to a wall that supports floor framing members (joists).
Fire block: Installed to limit fire spread in concealed spaces-often mid-wall or mid-stud cavity, not in this floor-to-wall position.
Girt: A horizontal framing member in a wall, usually in steel-frame or post-frame construction, not in conventional wood framing for floors.
Lateral shear plate: A metal plate for shear transfer, not applicable here.
PDD References:
ARE 5.0 PDD "Structural Systems-Wood framing details"
IBC §2308.4-Floor framing requirements
AWC (American Wood Council) "Wood Frame Construction Manual" Ledger attachment details
問題 #47 
Refer to the exhibit.
An architect is designing a multipurpose room that will operate daycare services as well as exercise classes.
The multiple occupancies within the space utilize components of the same means of egress system.
What is the occupant load factor that should be used in calculating egress?
答案:D
解題說明:
Step-by-Step Reasoning
1. Identify the occupancies from the question:
* Day care services # Occupant load factor = 35 net (from table in the exhibit)
* Exercise classes # Occupant load factor = 50 gross (also from table in the exhibit, under "Exercise room")
2. Determine how to calculate the occupant load for multiple occupancies:
According to IBC 2018, Section 1004.1.2 (Areas without fixed seating) and NCARB PDD study materials:
When multiple occupancies share the same means of egress system, the occupant load for the whole space shall be the sum of the occupant loads of the various occupancies.
However, if the space is not divided and is used interchangeably (multipurpose), the most stringent occupant load factor is applied to the entire area.
3. Applying the code:
* The multipurpose room is used for both daycare and exercise.
* Since the same space is used for different functions at different times (not divided), the most restrictive occupant load factor (the smaller number) should be used.
* Smaller occupant load factor = 35 net (Day care) vs. 50 gross (Exercise room).
4. Why "net" vs. "gross" matters here:
* Net floor area excludes certain spaces like walls, corridors, mechanical rooms.
* Gross floor area includes the entire footprint.
* Even though "net" typically results in a smaller area, when calculating load factors, the smaller occupant load factor number results in a larger occupant load - making it more restrictive for egress.
5. Conclusion:
The correct occupant load factor to use for this multipurpose space = 35 net (Day care), as it results in the largest occupant load and is the most restrictive for egress design.
NCARB ARE 5.0 PDD Study Guide References:
* Content Area: Code Analysis - Occupant Load & Egress Sizing
* IBC 2018, Section 1004.1.2 - Areas without fixed seating, determining occupant load for multiple functions
* Architectural Graphic Standards - Occupant Load Calculation examples
* Building Codes Illustrated by Ching & Winkel - Chapter on Occupancy Load Factors and Egress Requirements
問題 #48
......
每個人都有自己的夢想,你夢想呢,是升職、是加薪或者等等。我的夢想的通過NCARB的PDD考試認證,我覺得有了這個認證,所有的問題都不是問題,不過想要通過這個認證是比較困難,不過不要緊,我選擇VCESoft NCARB的PDD考試培訓資料,它可以幫助我實現我的夢想,如果也有IT夢,那就趕緊把它變成現實吧,選擇VCESoft NCARB的PDD考試培訓資料,絕對信得過。
PDD參考資料: https://www.vcesoft.com/PDD-pdf.html
在VCESoft PDD參考資料的指導和幫助下,你完全可以充分地準備考試,並且可以輕鬆地通過考試,為您提供便捷的在線服務爲您解決任何有關PDD擬真試題的疑問,考試過程很輕松,通過該考試需要高度專業的知識,如果你還欠缺這方面的知識, VCESoft PDD參考資料可以為你提供知識的來源,眾所周知,NCARB PDD 認證培訓在相關行業領域內正在歷經一個需求不斷增大的時代,VCESoft提供的資料比較全面,包括當前考試題目,是由VCESoft的專家團隊利用他們的豐富的經驗和知識針對NCARB PDD 認證考試研究出來的,NCARB PDD 題庫下載 如果你正在漫無目的地到處尋找參考資料,那麼趕快停止吧。
周凡巡邏完之後,又背著有些困乏的小柳回了帳篷之內,李魚找到了張金水,在VCESoft的指導和幫助下,你完全可以充分地準備考試,並且可以輕鬆地通過考試,為您提供便捷的在線服務爲您解決任何有關PDD擬真試題的疑問。
考試過程很輕松,通過該考試需要高度專業的知識,如果你還欠缺這方面的知識, VCESoft可以為你提供知識的來源,眾所周知,NCARB PDD 認證培訓在相關行業領域內正在歷經一個需求不斷增大的時代。
順便提一下,可以從雲存儲中下載VCESoft PDD考試題庫的完整版:https://drive.google.com/open?id=1UhRMlk3rqY6tQEMDJDGvrA6QVC6IocWA